Level 2 EV Charger Installation (GTA ONLY)
1. Installation Scope
Assessment: Conduct on-site panel load check and capacity verification.
Permitting: File ESA Notification of Work (Electrical Permit) prior to installation.
Wiring & Circuit: Supply and install a dedicated 240V double-pole circuit breaker and copper wiring (hardwired connection or industrial NEMA 14-50 outlet with GFCI protection).
Mounting & Hookup: Securely wall-mount the charger and complete all electrical connections.
Testing & Inspection: Test voltage, ground, and charging functionality; coordinate ESA inspection and provide final Certificate of Acceptance.
2. Pricing & Deposit
Estimated Cost Range: $500 – $1,200 CAD (final price to be confirmed on-site by electrician based on run distance and structural layout).
Booking Deposit: $50 due upon booking to schedule the service (credited toward the total job cost).
3. Exclusions
Panel Upgrades: Electrical panel upgrades or service capacity increases (e.g., 100A to 200A) are NOT included in this pricing.
Product Specification
General Features
General Features
- Charging mode: Level 2
- Vehicle connection: SAE J1772 or NACS1 plug with 18' cable
- AC power output: 7.4kW/32A, 9.6kW/40A, 11.5kW/48A
- Mounting options: Wall and post mounting
- Digital Screen: 2.8" LCD Screen
- Charging status LED: Yes
- Load management: via OCPP platform
Communication, Certificates and Standards
Communication
- Interfaces: Ethernet, WiFi, Bluetooth
- User authentication: App
- Back-end protocol: OCPP 1.6J
- Software upgrade: Over the air (OTA)
Certificates and Standards
- ETL listed: UL2594, CSA C22.2#280
General Design and Electrical Details
General Design
- Environmental rating: NEMA 3R
- Dimensions (HxWxD): 325.3 x 230.6 x 143 mm
- Weight: 6.6 kg
- Ambient conditions: Operating temperature -30°C to +50°C, 5% to 95% RH
- Shell material: PC + Glass
- Colours: Grey, PC
Electrical Details
- Power supply voltage: Single phase, 208V/240V AC, 60 Hz
- Rated current settings: 32A, 40A, 48A
- Power wiring: 3 Wire, L1, L2 plus ground
- Earth leakage protection & ground fault protection: Yes
- Overvoltage/undervoltage protection: Yes
- Over current protection: Yes
- Operating altitude: ≤ 2000m